Heat of Hydration Apparatus
EN196-8, BS 4550, 1370, ASTM C186
When Portland or hydraulic cement is mixed with water, heat is generated as a result of the exothermic reaction. The heat generated by cement’s hydration raises the temperature of concrete and this temperature rise causes expansion while concrete is hardening, especially under conditions when heat can not be readily released.
Heat of Hydration Calorimeter is used for determining the heat of hydration of low heat Portland and hydraulic cement. The apparatus consists of a Dewar flask housed in an insulated box, an electric stirrer, a filler funnel and a high resolution battery operated electronic thermometer.
Features
- Displays, saves and prints ΔT, Min., Max. and Mean Values
- Audible alarm if limit values are exceeded
- Resolution 0.001°C
- PT100 Probe Measuring Range -40 to +300°C
- Protection class IP65
- Accuracy 0.05°C
- Memory 10.000
- Complete with resolution test certificate
- Supplied complete with MS EXCEL template for data processing